Skip to main content
Logo
Back to Blog List

How to check motor alarms?

LMS_YinHao2025-09-1533 views

Method 1: Use NIMstudio software to view the motor's historical alarms and current alarms:

1. Open the "Console -> Fault Log" interface in the debugging software.

 

2. Click "History Alarm" to view the motor's alarm history.

 

3. Click "Clear History Alarm" to save the alarm information that represents the motor's current alarm.


Method 2 - Using a message to read the current motor alarm:

 

1. Send a message to read the error code address 603F (037F):

 

CANopen601 40 3F 60 00 00 00 00 00
Modbus01 04 03 7F 00 01

2. Identify the alarm by referring to the table below:

 

Alarm codeAlarm contentDefault alarm typeDefault fault response codeWhether to reset automatically603F (error code)
0x2300Motor overcurrentFault0No0x2300
0x4012311Motor overloadWarning4Yes0x2311
0x3002312Motor stallPause and lock3No0x2312
0x13210Power supply overvoltageFault0Yes0x3210
0x1013220Power supply undervoltageFault1Yes0x3220
0x13211Over-discharge voltage faultFault1Yes0x3211
0x3285Output phase faultFault0No0x3285
0x14210Overtemperature alarmFault0Yes0x4210
0x14220Undertemperature alarmFault0Yes0x4220
0x5080Drive fault*Fault0No0x5080
0x5540Flash operation fault*Fault0No0x5540
0x5541Flash initialization fault*Fault0No0x5541
0x4005542Flash checksum error warning*Warning4No0x5542
0x5543Flash user area parameter missingFault0No0x5543
0x4005544Power-off position storage errorWarning4No0x5544
0x4005545Power-off save data not savedWarning4No0x5545
0x6000Hardware initialization fault*Fault0No0x6000
0x16320Parameter setting errorFault0Yes0x6320
0x6321Registration fault*Fault0No0x6321
0x7301Encoder battery low voltage faultFault0No0x7301
0x4017302Encoder battery undervoltage alarmWarning4Yes0x7302
0x1017304Encoder multi-turn count errorFault1Yes0x7304
0x7305Z pulse fault*Fault0No0x7305
0x7306Encoder fault*Fault0No0x7306
0x4017307Encoder warning*Warning4Yes0x7307
0x7309Encoder internal faultFault0No0x7309
0x17310OverspeedFault0Yes0x7310
0x17501Communication faultFault0Yes0x7501
0x8610Home return timeoutFault0No0x8610
0x8611Position errorFault0No0x8611
0x3018613Software limit errorPause and lock3No0x8613
0x3018614Limit switch errorPause and lock3No0x8614
0x8700Synchronization fault*Fault0No0x8700
0x3285Output phase faultFault0No0x3285
0x4018615Curve planning calculation errorWarning4Yes0x8615
0x18616Target position overflowFault0No0x8616
0x5018617Curve planning parameter too smallignore5Yes0x8617
0XFF01Motor parameter identification fault*Fault0No0xFF01
0x401FF02Unable to execute command*Warning4No0xFF02